Hitachi High-Tech (Shanghai) Kasa da Kasa Kasuwanci Co., Ltd.
QShortcut>QShortcut>LA8080 Ultra-high gudun cikakken atomatik amino acid analyzer
LA8080 Ultra-high gudun cikakken atomatik amino acid analyzer
LA8080 m da kuma ci gaba da Hitachi shekaru na amino acid analyzer R & D kwarewa, kayan aiki aminci da kuma kwanciyar hankali high, da kuma kyakkyawan
@ action

LA8080 Ultra-high gudun cikakken atomatik amino acid analyzer

  • Shawarwari
  • Buga

LA8080超高速全自动氨基酸分析仪

LA8080 m da kuma ci gaba da Hitachi shekaru na amino acid analyzer R & D kwarewa, kayan aiki aminci da kuma kwanciyar hankali high, da kuma kyakkyawan aiki.
Cikakken sarrafa kansa aiki, mai sauƙi don amfani ko da sabon. Cikakken la'akari da mai amfani da aiki hangen nesa, samar da m aiki yanayi.

  • siffofi

  • aikace-aikace

  • Alamar

  • muryar developer

  • R & D Tarihi

siffofi

Tsarin ergonomic

Ka yi la'akari da abubuwa da yawa kamar hangen nesa na mai amfani, halayen aiki.

Easy aiki

Kayan aiki zane mai kyau, bi da pre-zane ra'ayi. Kayan aiki ne sosai m, sauki don daukar kwalaben reagent da samfuran.

Ajiye Space Design

Gane da babban aminci da kwanciyar hankali na Hitachi Amino Acid Analyzer, za a iya zaɓar ƙasa da tebur. Tsarin tebur mai ƙarfi, girman kayan aiki ya ragu da kashi 30%, za a iya sanya shi kai tsaye a kan teburin gwaji don adana sarari.

Yi amfani da high aminci da kwanciyar hankali na post-derivative hanyar Triketone column

Binciken kyakkyawan hanyoyin bincike na samfurin da ya gabata.

High aminci da kuma kwanciyar hankali analytical fasaha

Binciken hanyar bincike na samfurin da ya gabata, seamless haɗi, don Allah tabbatar da amfani.

Misali na bincike: Tsarin bincike na yau da kullun (protein hydrolysis)

Don Allah zaɓi hanyar bincike don bincike bisa ga dalilin gwaji. Kasuwancin buffers da kuma derivatives reagents za a iya amfani da kai tsaye, ba tare da daidaitawa. Rashin kwanciyar hankali na Rashanone yana da rashin kwanciyar hankali, yawanci yana buƙatar ajiya a cikin sanyaya, amma Hitachi Amino Acid Analyzer yana haɗuwa da mafita biyu a ainihin lokacin kafin amsawar da aka samo, ba tare da buƙatar sanyaya ba.

Wide aikace-aikace

Har zuwa 6 nau'ikan buffer za a iya amfani da, column zafin jiki akwatin kuma za a iya saita lokaci gradient zafin jiki iko, mai amfani zai iya sassauci ƙirƙirar bincike hanyoyin.

aikace-aikace

AS/AAA-001_C Binciken samfurin halitta - binciken tsarin amino acid Saukewa
AS/AAA-002_C Biological Sample Analysis - Amino acid gwaji na culture ruwa Saukewa
AS/AAA-003_C Binciken samfurin da aka haɗa a cikin littafin Japan Pharmaceutical na 16 Saukewa
AS/AAA-004_C Binciken chains da isochain a cikin elastomer abinci kasa Saukewa
AS/AAA-005_C Binciken kwayoyin halitta - binciken tsarin oxytocin amino acid na shirye-shiryen peptide Saukewa
AS/AAA-006_C Binciken kwayoyin halitta - binciken tsarin amino acid na shirye-shiryen peptide wanda ya dogara da calcin Saukewa
AS/AAA-007_C Misali na dipeptide (alanine glutamine) amino acids a cikin al'ada Saukewa
AS/AAA-008_C Binciken kwayoyin halitta - binciken tsarin amino acid na shirye-shiryen peptide wanda ya dogara da calcin Saukewa
AS/AAA-009_C Matsayin L-alanine Saukewa
AS/AAA-010_C Ƙididdigar L-Lysine Acetate Saukewa
AS/AAA-011_C Matsayin L-proline Saukewa
AS/AAA-015_E Tsaro kwanciyar hankali analysis na glutamine da trystane Saukewa
AS/AAA-016_E Binciken amino acids na furotin a cikin kaji Saukewa
LC080049_E Ana nazarin amino acids na yau da kullun a cikin fodar soya ta hanyar protein hydrolysis Saukewa
LC080050_E Amino acid kyauta a cikin cane, cucumber, watermelon, ƙarin abin sha Saukewa
LC090033A_E Binciken amino acids a cikin haɗin abinci Saukewa
LC090034A_E Binciken amino acid a cikin abincin rabbit Saukewa

An mayar da hankali kan karatun tushen ingantaccen chromatography mai ruwa, wanda ya haɗa da "Ka'idodin ingantaccen chromatography mai ruwa da tsarin tsari" zuwa "Amfanin hanyoyin gwaji daban-daban".

  • High-inganci ruwa chromatography tushe darasi
  • Gyara da sabis

Alamar

Alamar (protein hydrolysis)

Alamar (protein hydrolysis)
Net bincike lokaci 30 min (Net)
Kula da lokaci repeatability CV 0.3 % (Arg)
Peak yankin repeatability CV 1.0 % (Gly, His)
Gano iyaka 2.5 pmol (S/N=2, Asp)

Nazarin Unit

Sashen Nazarin
Chromatography ginshiƙi Girma: 4.6 mm ID × 60 mm *
Resin: Hitachi keɓaɓɓun ion musayar resin
infusion famfo Kulawa kewayon: 0.001 - 1.000 mL / min
Bayar da matsin lamba: 0 ~ 34 MPa
6 nau'ikan buffer gradient rabuwa
atomatik Sampler Hanyar samfurin: kai tsaye samfurin
Samfurin kwalba girman: 1,500 μL
Samfurin kwalba: 120 (Refrigeration Unit (zaɓi): 100)
Samfurin girma: 0.5 ~ 100 μL (daidaitaccen allura)
Column zafi Box Hanyar: Pallet zafin jiki sarrafawa
Saita zafin jiki: 10 ~ 90 ° C (karuwa: 1 ° C)
Amsa Unit Hanyar: Reactor
Saita zafin jiki: 50 ~ 140 ° C (karuwa: 1 ° C)
Mai ganowa Spectral tsarin: watsi bambanci concave diffraction grating
tsawon raƙuman ruwa: 570 nm, 440 nm

Sauran

Sauran
Bayani size (ba tare da kwamfuta) 700(W)×600(D)×1,380(H) mm
Nauyi (ba tare da kwamfuta) kimanin 175 kg
zafin jiki range 15~35 °C
wutar lantarki 220, 230, 240 V ± 10 V, 800 VA, 50 ko 60 Hz
Nitrogen Mai amfani da kansa
  • * Standard Chromatography ginshiƙi

muryar developer

Kyakkyawan aiki, Compact zane, Easy aiki
An haife sabon tsara na amino acid analyzer!
Hitachi babban saurin amino acid analyzer LA8080

Hitachi ya ƙaddamar da na'urar nazarin amino acid na farko a 1962, wanda ya haɓaka gano abubuwan da ke cikin amino acid a cikin abinci, abinci da magunguna. LA8080 ya dogara ne akan samfurin gargajiya L-8900, wanda aka ƙaddamar a 2005, wanda aka gina shi a hankali a cikin shekaru goma don ƙaddamar da shi ga kasuwa.
LA8080 yana bin manyan ra'ayoyi uku:
Na farko, kyakkyawan aiki. Fasahohin Hitachi na musamman da yawa don ƙarin inganta aikin.
Na biyu, ƙirar Compact. Ka kiyaye samfurin ƙasa na gargajiya kuma ka ƙara samfurin tebur. Minimize kayan aiki yankin, zai iya ceton dakin gwaje-gwaje sarari, kai tsaye a kan gwaji tebur.
Na uku, aiki mai sauki. Inganta ingancin gwaji daga hangen nesa na ergonomics.

Hitachi High Speed Amino Acid Analyzer LA8080 yana jagorantar kirkire-kirkire tare da fasahar musamman, wanda ya himmatu don samar da kayan aiki masu kyau da kuma mafita masu yawa ga abokan cinikin binciken amino acid.

R & D Tarihi

Tarihin Hitachi Amino Acid Analyzer

日立氨基酸分析仪的历史

Bincike da ci gaban Hitachi Amino Acid Analyzer

Amino acid analyzer ne kayan aiki na kowane amino acid abubuwa a cikin samfurin bayani, yafi amfani da ingancin management na abinci, magunguna da abinci da sauransu, da kuma binciken sinadarai, gwajin ɓangare na uku da sauransu.
A 1958, Spackman, Stein, da Moore sun fara fasahar raba tsarin amino acid da hanyoyin bincike na atomatik ta amfani da hanyoyin bayan hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin hanyoyin.
A shekara ta 1962, masana'antar Hitachi ta yi nasarar samar da na'urar nazarin amino acid ta farko ta Japan KLA-2, tarihin na'urar nazarin amino acid ta Hitachi ya fara ne. A lokacin, binciken samfurin ɗaya yana ɗaukar lokaci na rana (sa'o'i 22). A cikin 1977, Hitachi ya gabatar da sabon samfurin 835, wanda ke da diamita na resin mai musayar ion a cikin ginshikin chromatography na 5mm kawai, wanda ya rage yawan ƙwayoyi idan aka kwatanta da samfurin ƙarni na farko. Saurin bincike kuma ya sami tsalle mai inganci, lokacin bincike ya rage zuwa mintuna 50. Bugu da ƙari, tare da ingantaccen tsarin ganowa, ƙwarewar ta kai sau 1000 fiye da KLA-2.
A ƙarshen watan Afrilu na shekara ta 1977, jirgin ruwan kamun kifi na Japan a cikin tekun New Zealand ya ceci gawar da ta yi kama da dabbobi masu ruwa, tare da manyan fin a kan gawar, wanda aka yi zaton zai iya zama Long Neck Dragon. "Sea Monster" taron a lokaci daya ya yi hasashen duniya. Don bincika daidai, Hitachi ya kawo fuskar gaba a kan teku zuwa masana'antar Nako kuma ya yi gwajin amino acid tare da sabon samfurin 835 na lokacin. Sakamakon ya nuna cewa samfurin ya ƙunshi furotin na musamman kamar hydroxyproline da oxylysine, wanda ya ƙayyade cewa shine ƙwayoyin ƙwayoyin shark. A ranar 25 ga Yuli, wannan labarin ya mamaye rubutun jarida na safiya a duk faɗin ƙasa, a cikin watanni uku kawai.
Daga baya, Hitachi ya ƙaddamar da L-8500 a 1986, yana amfani da resin mai musayar ion na 3μm wanda aka fara masana'antu don rage lokacin bincike zuwa mintuna 30. A cikin 1977 L-8800, na farko kwamfuta sarrafawa, da amfani da amsawa ginshike samuwa. An ƙaddamar da L-8900 a 2005, mafi kyawun aiki, hanyoyin da aka gina, kayan aikin aiki mafi sauki, ya zama samfurin gargajiya, wanda abokan cinikin kasar Sin suka fi so da amincewa da shi.
An gabatar da sabon samfurin LA8080 a cikin 2017. Yayin da ya gaji fa'idodi kamar kyakkyawan aikin Hitachi Amino Acid Analyzer da amincin bayanai da kwanciyar hankali, yana kuma ƙaddamar da ƙirar tebur mai ƙarancin ƙarancin ƙira don magance matsalolin gaskiya game da rashin isasshen sararin dakin gwaje-gwaje.

*
Asalin da aka yi amfani da shi: Masako Ito, Masako Sengamatsu, Masako Bae, Masako Morizaki, Yushi Suzuki, Masako Fukuda, Takaru Yagi, Masako Dai, Kunayiya, Toyosaki Farming, S. I. NEWS, 61, 5360-5364 (2018).
  • https://www.hitachi-hightech.com/cn/about/news/2020/.html?version=

Hitachi amino acid analyzer tarihin bidiyo

Aikace-aikacen Magunguna (Amino Acid Analyzer) Gabatarwa

Ya ƙunshi misalai na gwaji 12 da kuma bayanan ƙarin.
An lissafa misalai na aikace-aikace a fannin magunguna da magungunan halitta da aka ƙunshi a cikin Bayani na Japan na 16.
Don Allah tambayi mu don ƙarin bayani.

aikace-aikace

Gabatar da cikakken atomatik amino acid analyzer auna misali.

High-inganci ruwa chromatography tushe darasi

Gabatar da tushen ingantaccen chromatography na ruwa, gami da "Ka'idoji da tsarin tsarin ingantaccen chromatography na ruwa" zuwa "halayen hanyoyin gwaji daban-daban".

Kimiyya Ring

Gabatar da alamar Hitachi High-Tech Science Group wanda ke nufin jagorancin fannin kimiyya da fasaha.

QNetworkAccessFileBackend
  • QShortcut
  • QShortcut
  • QShortcut
  • Email
  • Dakata
  • @ action
  • @ action

Ayyuka masu nasara!

Ayyuka masu nasara!

Ayyuka masu nasara!